Call: 734.761.1270E-mail: info@enmet.com
All Categories > Medical/Aerospace/Specialty Monitors > ISA-60M Monitor with MRI-5175 Oxygen Sensor/Transmitter > ISA-60M 1-3 Channel Oxygen Monitor with MRI-5175 O2 Sensor/Transmitter > ISA-60M 1-3 Channel Oxygen Monitor with MRI-5175 O2 Sensor/Transmitter  
Request Information

ISA-60M

larger image

ISA-60M 1-3 Channel Oxygen Monitor with MRI-5175 O2 Sensor/Transmitter






Features · General Specifications · ISA-60M Monitor Specifications · MRI-5175 Transmitter Specifications · Oxygen Sensor Specifications · Sensor Cable

Features
  • Long-life oxygen sensor
  • The ISA-60M has 3 channel capacity utilizing 4-20 mA; Up to 4 channels can be displayed using RS-485 Modbus
  • System can be expanded
  • Continuous monitoring of the environment
  • The ISA-60M provides continuous LCD display of oxygen concentrations
  • Menu driven operation, maintenance and calibration procedures
  • Audio and visual alarms indicate unsafe conditions
  • Alarm acknowledgement, including audio defeat capability
  • 4-20 mA output for each channel, plus RS-485 Modbus
  • 5 oxygen alarm relay contacts
  • Fault relay and visual fault alarm
  • Classified to UL 60601-1
    IEC 60601-1 & CSA 22.2, No. 601-1

1, 2 or 3 Channel Models Available:

P/N 04650-001 ISA-60M, single-channel with one MRI-5175 O2 Sensor/Transmitter
P/N 04650-002 ISA-60M, dual-channel with two MRI-5175 O2 Sensor/Transmitters
P/N 04650-003 ISA-60M, three-channel with three MRI-5175 O2 Sensor/Transmitters



General Specifications

Temperature Range

32 to 104 °F (0 to 40 °C)

Relative Humidity

10-99% RH, non-condensing

Atmospheric Pressure

20 to 36 inHg (68 to 122 kPa)

Approval

Classified to UL 60601-1
IEC 60601-1 & CSA 22.2, No. 601-1

Replacement Parts and Accessories

04566-004 - Battery Backup and Charging System
66017-006 - Sensor/Transmitter Cable, 3-conductor, 18 AWG, shielded
67016-1152 - Oxygen Sensor


ISA-60M Monitor Specifications

Standard Alarm Points

19.5% & 17% decreasing oxygen

Display

2 Line, 16 Character, Dot Matrix LCD

Visual Alarm

LEDs

Audible Alarm

Piezo Electric

Horn

95 dB at 2 feet

Alarm Relay

5 programmable oxygen alarm relays, plus fault. All relays are programmable latching or non-latching, dry SPDT, 10 amps (resistive load only) at 110 VAC.

Analog Output

4-20 mA

Digital Output

RS-232 Modbus and RS-485 Modbus

Connection

Strain Relief (2 supplied) for 0.20" to 0.35" OD Cable

Power

100 to 240 VAC and/or 12 VDC, 15 Watts

Enclosure

Thermoplastic box with clear, hinged front cover, designed for NEMA 12 and 4X.

Size

10.5 x 8.5 x 5.8 in (27 x 22 x 15 cm)

Weight

8 lbs (3.6 kg)


MRI-5175 Transmitter Specifications

Visual Gas Alarm

3 Red LEDs

Visual Power/Fault

Green/Red LED

Analog Output

4-20 mA

Digital Output

RS-485 Modbus

Power Requirements

24 VDC from ISA-60M

Optional Audible Alarm

105 dB at 12 inches (30 cm)

Connection to ISA-60M

Strain Relief (1 supplied) for 24 VDC, 4-20 mA, 0.20" to 0.35" OD Cable

Enclosure

Fiberglass-reinforced Polyester Non-Magnetic Hardware

Dimensions

5 x 5 x 4 in (2 x 2 x 1.6 cm)

Weight

2 lbs (0.9 kg)


Oxygen Sensor Specifications

Type

Electrochemical

Range

0 to 30.0% by Volume Oxygen

Resolution

0.1% by Volume Oxygen

Typical Sensor Life

4 to 5 years


Sensor Cable
3-wire, Shielded Cable, Typically 18 to 20 AWG, User Supplied, UL Listed type CM, PLTC or TC



    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 MORE IMAGES 

· Oxygen in MRI

· ISA-60M External Features

· ISA-60M Internal Features

· MRI-5175 External and Internal Features

· MRI-5175 Dimensional Drawing

· ISA-60M Dimensional Drawing in Inches

· ISA-60M Ordering Information, Replacement Parts, Accessories and Calibration Equipment


Request Information
Site created by ThomasNet Web Solutions and powered by Navigator Platform
ENMET Corporation | Gas Detection for Health, Safety and Process Monitoring