AFS-50 Air Filtration System for Supplied-Air Respirators
>
P/N 03462-001
larger image
P/N 03462-001, AFS-50 Air Filtration System for Supplied-Air Respirators
The AFS-50 Air Filtration System by ENMET is designed to provide workers with high quality breathing air from a compressor, when equipped with an optional CO monitor. The AFS-50 system incorporates a two-stage prefilter/coalescer which removes oil, water, and solid particles, followed by an adsorber which removes unpleasant odor and taste from the supplied air. The coalescer is a high-efficiency filter that removes oil mist and fine (sub-micron) particles. The AFS-50 has 50 CFM capacity and is equipped with 4 outlet ports for connection to supplied-air respirators. The AFS-50 is compatible with a variety of ENMET carbon monoxide and oxygen monitors. The system is compact and can be supplied in a transit case or on a wall-mount plate, with or without a CO/O
2
monitor.
Features
·
Specifications
Features
Designed for assuring Grade D breathing air, when equipped with optional CO/O
2
monitor
(Optional CO monitors allow compliance with OSHA Respiratory Standard CFR 1910.134)
Includes 4 outlets for connection to supplied-air respirators
50 CFM capacity
Two-stage prefilter/coalescer removes oil, water, and solid particles
Pressure drop gauge automatically indicates need to change filter
Adsorber removes unpleasant odor and taste
Compatible with a variety of ENMET carbon monoxide and oxygen monitors
Standard with wall-mount brackets
Can be supplied in the following configurations:
On optional wall-mount plate or with optional CO/O
2
monitor
Specifications
Inlet Pressure
Maximum 150 psi
Manifold Pressure
Maximum 100 psi, System Supplied with Regulator and 160 psi Gauge
Pressure Relief Valve
Factory set to open at 100 psi and limit Manifold Pressure
Total Air Capacity
Maximum 50 CFM
Outlet Connections
Supplied with 4 Quick Disconnects (Hansen Series 1000 Compatible) for Connecting Respirators. A Fifth Quick Disconnect can be used for connecting a CO/O
2
Monitor or additional Respirator.
Inlet Port
1/2” NPT, Female
Prefilter/Coalescer
Removes Oil, Water and Solid Particles
Drain, Prefilter/Coalescer
For periodically removing collected Fluids in the Prefilter Bowl
Pressure Drop Indicator
Indicates the condition of the Prefilter/Coalescer Element and when to change it
Adsorber
Removes unpleasant Odor and Taste from the Air System
Adsorber Drain
For periodically removing collected Fluids in the Adsorber Bowl
Size
12" W x 15" H x 5" D
Weight
10 lb
Please wait…
Download PDF
Download PDF
Email This Page
Save To Favorites
DOWNLOADS
AFS-50 Literature
(PDF, 173KB)
AFS-50 Manual
(PDF, 79KB)