Call: 734.761.1270E-mail: info@enmet.com
All Categories > CO-Guard-MOS Respiratory Air Line Monitor with MOS Sensor > P/N 03481-040  
Request Information

CO-Guard-MOS

larger image

P/N 03481-040, CO-Guard-MOS Respiratory Air Line Monitor with MOS Sensor



CO-Guard-MOS is a compact, easy to install and operate, compressed air line CO monitor. The instrument incorporates a backlighted digital display, rugged, long-life, metal oxide semiconductor (MOS) sensor and hydrocarbon filter for trouble-free and reliable operation.

CO-Guard-MOS is designed for installation in nonhazardous (not potentially explosive) locations, and is suitable for use in a wide variety of applications ranging from automotive, and similar, paint spray operations to wood finishing. This monitor can be used in most commercial or industrial processes which utilize supplied-air respirators.




Features · Specifications

Features
  • Compact Design
  • Digital Display
  • User Programmable Alarms & Relays
  • 4-20 mA Output
  • RS-485 Digital Communication Capability
  • 100-240 VAC, 24 VDC Power Options
  • "Intelli-Cal" Push-Button Calibration Procedure
  • 3 Levels of Alarms
  • Protected Maintenance Functions
  • Audio and Visual Alarms
  • High Integrity Polycarbonate Enclosure
  • High Capacity Relays




Specifications

Range

0-50 ppm CO

Alarm Levels

Alarm 1: 10 ppm CO, user adjustable
Alarm 2: 20 ppm CO, user adjustable
Alarm 3: 35 ppm CO, user adjustable

Alarm Adjustment

All Three Alarms are user adjustable between 10 to 50 ppm

Audible Alarm

105 dB at 30 cm (12 inches), factory set to activate at Alarm 1, user adjustable

Visual Gas Alarm

3 Red LEDs

Visual Power/Fault

Green/Red LED

Display

8 Character, High Contrast Dot Matrix LCD with Backlight

Sensor

Metal Oxide Semiconductor (MOS)

Response Time

T90 = 180 sec.

Accuracy

± 15% of reading

Temperature Range

32 to 122 °F (0 to +50 °C)

Outputs

Relays: 4 Form C, 10A SPDT Contacts, 3 Gas Alarms and 1 Fault
Analog: 4-20 mA
Digital: RS-485 Modbus

Power

100-240 VAC, 50/60 Hz and/or 24 VDC, 15W

Power Connection

Supplied with Strain Relief for 0.20 to 0.35 inch Diameter Cable

Inlet Air Line Connection

1/4" NPT Female; supplied with Male Quick Release Fitting (Milton 727, Hansen 1000 Compatible)

Sample Air Line

Approximately 10 feet between Monitor and Connection to facility Air Supply

Inlet Pressure

50 to 150 psi Air Supply Lines, Regulated 7 to 12 psi to Sensor

Enclosure

Polycarbonate

Size

7 x 5 x 3 in (18 x 13 x 8 cm)

Weight

2 lbs (0.9 kg)


    Download PDF Download PDF  
    Email Email This Page  
    Save To Favorites Save To Favorites
  

 MORE IMAGES 

· CO-Guard-MOS Internal Features

· CO-Guard-MOS External Features

· Calibration Equipment


 DOWNLOADS 

 width= CO-Guard-MOS Manual
(PDF, 276KB)

 width= CO-Guard-MOS Literature
(PDF, 318KB)


Request Information
Site created by ThomasNet Web Solutions and powered by Navigator Platform
ENMET Corporation | Gas Detection for Health, Safety and Process Monitoring