Search
By Part Number
By Keyword
Home
About Us
Technical Information
Material Safety Data Sheets (MSDS)
Gases Monitored
Products
Resources
Contact ENMET
Request Information
Call:
734.761.1270
E-mail:
info@enmet.com
Sensor/Transmitters,
Controllers, Samplers,
Single-Point Monitors
Medical, Aerospace &
OEM Products
Portable, Multi-Gas
Detectors
Personal, Single-Gas
Detectors
Respiratory, Compressed
Air Products
New/Featured
Products
Consulting Services,
Seminars and Expert
Witness Testimony
All Categories
>
Personal, Single Gas Detectors
>
Spectrum SP Series Portable Gas Detector with Integral Pump for Improved Monitoring Performance
>
View Items
Spectrum SP Series Portable Gas Detector with Integral Pump for Improved Monitoring Performance
Check up to five results to perform an action.
larger image
Gas detectors are designed for monitoring the environment by one of two methods, diffusion or sample draw. In the case of diffusion, natural forces are relied upon to cause the ambient air to interact with the gas sensor. As an alternative, the air sample can be drawn to the sensor using either a hand-operated, squeeze-bulb aspirator or a motorized sample pump. Obviously, the motorized pump is much more convenient and easier to use, and it can provide a continuous air sample to the sensor at a constant flow rate.
Sample draw reduces gas response time compared to natural diffusion, and it facilitates testing of valves, pipe connections, etc. for leaks, and enables the monitoring of remote areas or enclosed vessels where nonambient conditions may exist, such as, temperature extremes.
A properly designed sample draw system can improve the monitoring performance for most gases, particularly acid gases like Cl
2
and HCl. It also reduces the response times for gases to be detected at sub-ppm concentrations, such as, AsH
3
. And, most important, sample draw is required for the detection of some gases, most notably, HF and O
3
. It is for these reasons that the SPECTRUM SP Series was developed.
Spectrum SP Series Literature
Spectrum SP Series Manual
Please wait…
Download PDF
Download PDF
Email This Page
Save To Favorites
Results Per Page :
25
50
100
200
Results 1 - 13 of 13
1
P/N
Gas Detected
Range
LDL
Alarm 1
Alarm 2
04818-0100
Chlorine, Cl
2
10.0 ppm
0.5 ppm
1 ppm
5 ppm
04818-0200
Hydrogen Sulfide, H
2
S
200 ppm
5 ppm
10 ppm
25 ppm
04818-0400
Hydrogen Chloride, HCl
20.0 ppm
1 ppm
5 ppm
10 ppm
04818-0500
Sulfur Dioxide, SO
2
20.0 ppm
1 ppm
5 ppm
10 ppm
04818-0700
Hydrogen fluoride, HF
10.0 ppm
1 ppm
3 ppm
6 ppm
04818-0800
Ozone, O
3
0.99 ppm
0.05 ppm
0.10 ppm
0.20 ppm
04818-1200
Carbon monoxide, CO
1000 ppm
5 ppm
35 ppm
200 ppm
04818-1500
Hydrogen, H
2
1000 ppm
30 ppm
200 ppm
750 ppm
04818-1700
Nitrogen Dioxide, NO
2
10.0 ppm
1.5 ppm
3 ppm
5 ppm
04818-1750
Nitric Oxide, NO
100 ppm
5 ppm
25 ppm
50 ppm
04818-2400
Ammonia, NH
3
100 ppm
7 ppm
25 ppm
50 ppm
04818-4001
Arsine, AsH
3
0.99 ppm
0.05 ppm
0.05 ppm
0.10 ppm
04818-4003
Silane, SiH
4
30 ppm
4 ppm
5 ppm
10 ppm
Results 1 - 13 of 13